| Sign In | Join Free | My bjjsgy.com |
|
Brand Name : IFM
Model Number : SV4200
Certification : 3C
Place of Origin : GERMANY
MOQ : 1
Price : $383/piece
Payment Terms : T/T
Supply Ability : 1piece in stock
Delivery Time : 3 day
Packaging Details : 120*80*50mm
Weight[g] : 474
Dimensions[mm] : 110 x 45 x 72
System : gold-plated contacts
| Product characteristics | ||||||||||
| Number of inputs and outputs | Number of digital outputs: 2 | |||||||||
| Measuring range | 1...20 l/min | 0.06...1.2 m³/h | ||||||||
| Process connection | threaded connection G 1/2 DN8 | |||||||||
| Application | ||||||||||
| Special feature | Gold-plated contacts | |||||||||
| Application | for industrial applications | |||||||||
| Media | water; glycol solutions; coolants | |||||||||
| Medium temperature [°C] | -10...90 | |||||||||
| Pressure rating [bar] | 12 | |||||||||
| SV4200 | ||||||||||
| Vortex flow meter with display | ||||||||||
| SVR12XXXIRKG/US-100 | ||||||||||
| Pressure rating [Mpa] | 1.2 | |||||||||
| Note on pressure rating | up to 40 °C | |||||||||
| MAWP (for applications [bar] | 3.9 | |||||||||
| according to CRN) | ||||||||||
| Electrical data | ||||||||||
| Operating voltage | [V] | 18...30 DC | ||||||||
| Current consumption | [mA] | < 30 | ||||||||
| Min. insulation resistance | [MΩ] | 100; (500 V DC) | ||||||||
| Protection class | III | |||||||||
| Reverse polarity protection | yes | |||||||||
| Power-on delay time | [s] | < 3 | ||||||||
| Inputs / outputs | ||||||||||
| Number of inputs and outputs | Number of digital outputs: 2 | |||||||||
| Outputs | ||||||||||
| Total number of outputs | 2 | |||||||||
| Output signal | switching signal; frequency signal; IO-Link; (configurable) | |||||||||
| Electrical design | PNP/NPN | |||||||||
| Number of digital outputs | 2 | |||||||||
| Output function | normally open / normally closed; (parameterisable) | |||||||||
| Max. voltage drop switching output DC | [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC | [mA] | 100 | ||||||||
| Short-circuit protection | yes | |||||||||
| Overload protection | yes | |||||||||
| Measuring/setting range | ||||||||||
| Measuring range | 1...20 l/min | 0.06...1.2 m³/h | ||||||||
| Display range | 0...24 l/min | 0...1.44 m³/h | ||||||||
| Resolution | 0.1 l/min | 0.005 m³/h | ||||||||
| Set point SP | 1.2...20 l/min | 0.07...1.2 m³/h | ||||||||
| Reset point rP | 1...19.8 l/min | 0.06...1.19 m³/h | ||||||||
| Frequency endpoint, FEP | 4...20 l/min | 0.24...1.2 m³/h | ||||||||
| Insteps of | 0.1 l/min | 0.005 m³/h | ||||||||
| Frequency at the endpoint [Hz] | 100.. | .1000 | ||||||||
| FRP | ||||||||||
| Measuring dynamics | 1:20 | |||||||||
| Temperature monitoring | ||||||||||
| Measuring range | [°C] | -10...90 | ||||||||
| Display range | [°C] | -30...110 | ||||||||
| Resolution | [°C] | 0.5 | ||||||||
| Set point SP | [°C] | -9...90 | ||||||||
| Reset point rP | [°C] | -10...89 | ||||||||
| Insteps of | [°C] | 0.5 | ||||||||
| Frequency start point, FSP | [°C] | -10...70 | ||||||||
| Frequency endpoint, FEP | [°C] | 10...90 | ||||||||
| SV4200 | ||||||||||
| Vortex flow meter with display | ||||||||||
| SVR12XXXIRKG/US-100 | ||||||||||
| Frequency at the endpoint [Hz] | 100...1000 | |||||||||
| FRP | ||||||||||
| Accuracy / deviations Flow monitoring | ||||||||||
| Accuracy (in the measuring range) | ± 2 % MEW; (water) | |||||||||
| Repeatability | ± 0,5 % MEW | |||||||||
| Temperature monitoring | ||||||||||
| Accuracy [K] | ± 1 | |||||||||
| Response times Flow monitoring | ||||||||||
| Response time | [s] | 1; (dAP = 0) | ||||||||
| Damping process value dAP | [s] | 0...5 | ||||||||
| Temperature monitoring | ||||||||||
| Dynamic response T05 / T09 [s] | T09 = 6 | |||||||||
| Software / programming | ||||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; frequency output; switch-on/switch-off delay; Damping; Display unit | |||||||||
| Interfaces | ||||||||||
| Communication interface | IO-Link | |||||||||
| Transmission type | COM2 (38,4 kBaud) | |||||||||
| IO-Link revision | 1.1 | |||||||||
| SDCI standard | IEC 61131-9 | |||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | |||||||||
| SIO mode | yes | |||||||||
| Required master port type | A | |||||||||
| Process data analogue | 2 | |||||||||
| Process data binary | 2 | |||||||||
| Min. process cycle time [ms] | 3 | |||||||||
| Supported DeviceIDs | Type of operation | DeviceID | ||||||||
| Default | 484 | |||||||||
| Operating conditions | ||||||||||
| Ambient temperature | [°C] | 0...60 | ||||||||
| Note on ambient temperature | medium temperature < 80 °C | |||||||||
| medium temperature < 90 °C: 0...50 °C | ||||||||||
| Storage temperature | [°C] | -20...80 | ||||||||
| Protection | IP 65; IP 67 | |||||||||
| Tests / approvals | ||||||||||
| EMC | DIN EN 61000-6-2 | |||||||||
| DIN EN 61000-6-3 | ||||||||||
| SV4200 | ||||||||||
| Vortex flow meter with display | ||||||||||
| SVR12XXXIRKG/US-100 | ||||||||||
| CPA approval | model number | 001VO | ||||||||
| accuracy class | - | |||||||||
| maximum allowable error | ± 2 % FS | |||||||||
| Q (min) | 0,09 m³/h | |||||||||
| Q (t) | 0,24 m³/h | |||||||||
| Q (max) | 1,2 m³/h | |||||||||
| Shock resistance | DIN EN 60068-2-27 | 5 g (11 ms) | ||||||||
| Vibration resistance | DIN EN 60068-2-6 | with water / 10...50 Hz 1 mm | ||||||||
| with water / 50...2000 Hz 2 g | ||||||||||
| MTTF [years] | 342 | |||||||||
| UL approval | UL Approval no. | I001 | ||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | |||||||||
| Mechanical data | ||||||||||
| Weight | [g] | 474 | ||||||||
| Materials | stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U | |||||||||
| Materials (wetted parts) | stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM | |||||||||
| Tightening torque | [Nm] | 30 | ||||||||
| Process connection | threaded connection G 1/2 DN8 | |||||||||
| Remarks | ||||||||||
| Remarks | MW = measured value | |||||||||
| MEW = Final value of the measuring range | ||||||||||
| Pack quantity | 1 pcs. | |||||||||
| Electrical connection | ||||||||||
| Connector: 1 x M12; coding: A; Contacts: gold-plated | ||||||||||
| SV4200 | ||||||||||
| Vortex flow meter with display | ||||||||||
| SVR12XXXIRKG/US-100 | ||||||||||
| Connection | ||||||||||
![]() | ||||||||||
| OUT1: Flow monitoring - switching output - frequency output - IO-Link | ||||||||||
| OUT2: flow monitoring and temperature monitoring - switching output - frequency output | ||||||||||
| colours to DIN EN 60947-5-2 Core colours : | ||||||||||
| BK = black BN = brown BU = blue WH = white | ||||||||||
| Diagrams and graphs | ||||||||||
| Pressure loss | dP Pressure lossQ volumetric flow quantity | |||||||||
| SV4200 | ||||||||||
| Vortex flow meter with display | ||||||||||
| SVR12XXXIRKG/US-100 | ||||||||||
| pressure rating (bar) | ![]() | |||||||||
|
|
IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG Images |